| Feature supported by
wall switch. |
Wired Neo/Saturn wall
switches. |
Wireless Neo/Saturn
wall switches. |
| Communication cable not required? |
No, use C-Bus pink Cat5e cable. |
Yes, use C-Bus wireless RF comm's. |
| IR remote control support? |
Yes for wired Neo, optional for
Saturn. |
No, but RF remote is supported. |
| RF remote control support? |
No, but wired switches support IR. |
Yes, using C-Bus RF remote control. |
| C-Bus Dimmer or Relay quantities
unrestricted by switch location? |
Yes, because Dimmer and Relays are
located in C-Bus output units. |
No, 1 or 2 relays or dimmers max
inside each wireless wall switch. |
| LED colours software selectable? |
Yes, orange or blue
indicators. |
No, orange switch
indicators only. |
Safer near sinks/wet areas?
(no direct 240V connection required?) |
Yes, powered over C-Bus cable from
separate low voltage power supplies. |
No, uses conventional (often existing)
2-wire 240V wall switch wiring. |
Switch operation unaffected
by open-circuit 240V load? |
Yes. |
No, as switch power is obtained
through the load even when off. |